Delta’s Amplon R series is an online double-conversion rack-mountable UPS providing consistent sine-wave power to your critical equipment and reliable protection for IT equipment and data centers. The R series offers an output power factor of 0.9 and a best-in-class AC-AC efficiency of up to 93% for greater energy savings. The Amplon R series leads the industry in combining compact size, availability, flexibility, and low total cost of ownership.

Availability 

  1. True online double-conversion topology provides zero transfer time to ensure maximum protection of the equipment
  2. Watch-dog design of the DSP (Digital Signal Processor) increases reliability
  3. Cold-start capability provides temporary battery power when the utility power is out
  4. Operating temperature tolerance up to 50°C ensures critical loads’ continuity
  5. The Maintenance Bypass Box offers load continuity during battery replacement or other upgrades

Flexibility  

  1. Compact dimensions meet the needs of different rack cabinets
  2. Convertible rack and tower configuration in 2U size cabinet
  3. Excellent local communications through rotatable LCD display
  4. Intelligent management software connectivity via RS232, mini slot or USB port

 

Low Total Cost of Ownership

  1. Wide input voltage range reduces the chance of using the battery and extends battery life
  2. Intelligent battery management sustains battery life and performance
  3. High output power factor of 0.9 provides more real power to critical loads
  4. High input power factor (pf > 0.99) and low harmonic distortion (iTHD < 3%) save upstream investment
  5. Up to 93% AC-AC efficiency and 96% efficiency in ECO mode results in marked energy cost savings
  6. Fan speed control by load level and room temperature optimizes performance

Specifications

Model

DPS-160K / DPS-200K / DPS-300K / DPS-400K / DPS-500K

 
 

Power Rating
DPS-160K : 160kVA/144kW
DPS-200K : 200kVA/180kW
DPS-300K : 300kVA/270kW
DPS-400K : 400kVA/360kW
DPS-500K : 500kVA/450kW

 
 

Input
Nominal Voltage : 380/220, 400/230, 415/240 Vac (3 phase, 4-wire + G)
Voltage Range : 324~477 Vac (full load), 242~324 Vac (70%~100% load)
Current Harmonic Distortion : < 3% * Power Factor : > 0.99
Frequency : 45~65Hz

 
 

Output
Voltage : 380/220, 400/230, 415/240 Vac (3 phase, 4-wire + G)
Output Power Factor : 0.9 (standard); 1 (optional) **
Voltage Harmonic Distortion : ≤ 1.5% (linear load); < 1% (linear load) **
Voltage Regulation : ± 1% (static)
Frequency :50/60 ± 0.05 Hz
Overload Capability : ≤ 125%: 10 minutes; ≤ 150%: 1 minute

 
 

Display : Mimic LCD supports multi-language and LED indicators

 
 

Communication Interfaces
Standard : RS232 x 1, Smart slot x 2, Output dry contact x 6, Input dry contact x 7, (Input dry contact (two sets), REPO x 1, External battery cabinet status detection x 1, External battery cabinet temperature detection x 4), Parallel port x 2, USB port x 1

 
 

Conformance
Safety & EMC : CE,RCM

 
 

Other Features
Parallel Redundancy : Up to 8 units
Emergency Power Off : Local and remote
Event Log : 500 records

 
 

Efficiency
AC-AC : Up to 96%
ECO Mode : Up to 99%

 
 

Environment
Operating Temperature : 0 ~ 40°C
Relative Humidity : 0 ~ 95% (non-condensing)

Audible Noise
DPS-160K/200K : <70 dBA
DPS-300K/400K : <73 dBA
DPS-500K : <76 dBA
IP Protection : IP20

 
 

Physical
Dimensions(WxDxH)
DPS-160K/200K : 850 x 865 x 1950 mm
DPS-300K/400K/500K : 1600 x 865 x 1950 mm

Weight
DPS-160K/200K : 697 kg
DPS-300K/400K : 1200 kg
DPS-500K : 1220 kg

 
 

* When input harmonic distortion is less than 1%.
** Available in South East Asia, Australia and New Zealand.

All specifications are subject to change without prior notice.R-1K / R-2K / R-3K

 
 

Power Rating
R-1K : 1kVA/0.9kW
R-2K : 2kVA/1.8kW
R-3K : 3kVA/2.7kW

 
 

Input
Nominal Voltage : 200*/208*/220/230/240 Vac
Voltage Range
175 ~ 280 Vac (full load)
80 ~ 175 Vac (50% ~ 100% load)
Frequency : 50/60 Hz ± 10 Hz
Power Factor : > 0.99 (full load)
Current Harmonic Distortion : < 3%

 
 

Output
Power Factor : 0.9
Voltage : 200*/208*/220/230/240 Vac
Voltage Regulation : ± 1% (linear load)
Frequency : 50/60 Hz ± 0.05 Hz
Overload Capability
< 105%: Continuous
105 ~ 125%: 1 minute
125 ~ 150%: 30 seconds

Receptacle
R-1K : IEC C13 x 4
R-2K : IEC C13 x 2, IEC C19 x 1
R-3K : IEC C13 x 2, IEC C19 x 1

 
 

Efficiency
AC-AC
R-1K : 91%
R-2K/R-3K : Up to 93%
ECO Mode
R-1K : 95%
R-2K/R-3K : Up to 96%

 
 

Battery
Battery Voltage
R-1K : 24 Vdc
R-2K : 48 Vdc
R-3K : 72 Vdc
Charge Current : 4A (up to 8A with optional inbuilt charger)

 
 

Audible Noise**
R-1K : < 40 dB
R-2K/R-3K : < 43 dB

 
 

Display : LCD display and LED indicators

 
 

Communication Interfaces
Standard : Mini Slot x 1, RS-232 Port x 1, USB Port x 1

 
 

Conformance
Safety : CE

 
 

Physical
Dimensions (WxDxH)
R-1K : 440 x 335 x 88 mm
R-2K : 440 x 430 x 88 mm
R-3K : 440 x 430 x 88 mm

Weight
R-1K : 5.3 kg
R-2K : 9.0 kg
R-3K : 9.1 kg

 
 

Environment
Operating Temperature : 0 ~ 50°C***
Relative Humidity : 5 ~ 95% (non-condensing)

 
 

* When the UPS is de-rated to 90% of its capacity.
** If the UPS is running at <75% load and in room temperature.